cTnICK-MBMyo Combo Rapid Detection Kit
cTnICK-MBMyo Combo Rapid Detection Kit
cTnICK-MBMyo Combo Rapid Detection Kit
cTnICK-MBMyo Combo Rapid Detection Kit
cTnICK-MBMyo Combo Rapid Detection Kit

编号 :

cTnICK-MBMyo Combo Rapid Detection Kit


国内外技术工艺

国内外技术工艺

保证质量

保证质量

量身定制

量身定制

原厂采购

原厂采购

SEO标签:

Category:

WhatsApp:

隐藏域元素占位

Detailed introduction


▏cTnICK-MBMyo Combo Rapid Detection Kit

cTnI is primarily used for the auxiliary diagnosis of myocardial infarction. Similarly, creatine kinase isoenzyme is mainly applied in the auxiliary diagnosis of myocardial infarction, and myoglobin is also clinically utilized for the auxiliary diagnosis of myocardial infarction.

CK-MB is predominantly present in the myocardium. The detection of CK-MB significantly enhances the specificity of early diagnosis for acute myocardial infarction (AMI), making it one of the most commonly used cardiac enzymes in clinical practice and a sensitive indicator for early myocardial injury diagnosis.

Myoglobin, found in both skeletal and cardiac muscles, is the first non-enzymatic protein used to diagnose myocardial injury. 

The cTnI/CK-MB/Myo Combo Rapid Detection Kit is designed for the simultaneous qualitative detection of cardiac troponin I (cTnI), creatine kinase-MB (CK-MB) and myoglobin (Myo) in human whole blood, serum or plasma.

By combining three cardiac biomarkers in one rapid test, the kit provides healthcare professionals with complementary biomarker information to support the assessment of suspected myocardial injury.

The rapid format is suitable for professional diagnostic environments where timely cardiac biomarker testing and a straightforward workflow are important.

▏Intended Use

It in used for in vitro qualitative detection of cTnI, CK-MB, and Myo in human serum, plasma, and whole blood.

▏Storage And Stability

Unopened: Store sealed and protected from light at 4°C–30°C. Shelf life: 24 months.

Opened Test Kit: Use within 1 hour under humidity ≤60% and temperature 10°C–30°C.

▏Why Combine cTnI, CK-MB and Myoglobin?

A combination cardiac marker test can provide multiple biomarker results from a single testing workflow.

For clinical facilities, this can help:

● Obtain information on three cardiac biomarkers simultaneously
● Reduce the need to perform three separate rapid tests
● Simplify sample handling
● Support rapid assessment in time-sensitive clinical environments
● Provide complementary cardiac biomarker information
● Improve efficiency in professional point-of-care testing workflows

For IVD distributors, a 3-in-1 cardiac marker rapid test can also simplify product portfolios by covering multiple analytes within one kit.

▏Sample Types

The COEI cTnI/CK-MB/Myo Combo Rapid Detection Kit is designed for testing:

● Whole blood
● Serum
● Plasma

Compatibility with multiple specimen types provides greater flexibility for different professional diagnostic workflows.

Healthcare professionals should always follow the product Instructions for Use for specimen collection, preparation, sample volume and testing procedures.

▏Applications in Rapid Cardiac Biomarker Testing

Rapid cardiac biomarker testing may be required in clinical environments where healthcare professionals need timely laboratory information to support patient assessment.

Typical professional applications may include:

● Emergency departments
● Hospital laboratories
● Clinical laboratories
● Cardiology departments
● Urgent care environments
● Community healthcare facilities
● Point-of-care testing programs

The cTnI CK-MB Myoglobin rapid test is intended to provide biomarker information as part of the overall clinical assessment rather than replace electrocardiography, laboratory evaluation or medical judgment.

 

▏One Test Instead of Three Separate Cardiac Marker Tests

For professional testing environments, workflow efficiency is an important consideration.

Using separate cTnI, CK-MB and Myoglobin tests may require:

● Multiple test devices
● Additional specimen handling
● Separate test procedures
● Additional interpretation steps
● More inventory management

A cTnI/CK-MB/Myo Combo Rapid Detection Kit integrates the three biomarkers into one testing solution, helping simplify rapid cardiac biomarker testing.

This is particularly relevant for healthcare facilities and IVD distributors looking for practical multi-analyte POCT products.

▏Suitable for Professional POCT Applications

Point-of-care testing products are often selected based on more than analytical performance alone.

Healthcare facilities also consider:

● Testing workflow
● Specimen requirements
● Result turnaround
● Ease of operation
● Storage conditions
● Staff training requirements
● Quality-control procedures

A cardiac marker combo test can provide a convenient option for facilities that require rapid qualitative cardiac biomarker testing without performing multiple individual assays.

▏For IVD Distributors and Medical Diagnostic Suppliers

For distributors, cardiac biomarker tests represent an important part of cardiovascular and emergency diagnostic product portfolios.

The cTnI/CK-MB/Myo Combo Rapid Detection Kit may be particularly relevant for:

● IVD distributors
● Medical diagnostic importers
● Laboratory product wholesalers
● POCT solution providers
● Hospital procurement projects
● Diagnostic product dealers

Before purchasing, distributors should evaluate both product performance and long-term supply support.

 

FAQ-cTnICK-MBMyo Combo Rapid Detection Kit

 

What is a cTnI/CK-MB/Myo Combo Rapid Detection Kit?

A cTnI/CK-MB/Myo Combo Rapid Detection Kit is a multi-marker in vitro diagnostic test designed to detect cardiac troponin I, CK-MB and Myoglobin within one rapid testing format.

What biomarkers does the test detect?

The COEI combo test detects three cardiac biomarkers:

● cTnI — Cardiac Troponin I
● CK-MB — Creatine Kinase-MB
● Myo — Myoglobin

What specimens can be used?

The kit is designed for qualitative detection in whole blood, serum and plasma specimens.

Why test three cardiac biomarkers together?

Testing multiple biomarkers provides complementary information while allowing healthcare professionals to obtain three marker results through a consolidated rapid testing workflow.

Is cTnI more specific for myocardial injury than CK-MB and Myoglobin?

Cardiac troponin is currently the preferred biomarker for detecting myocardial injury because it has greater cardiac specificity. CK-MB and Myoglobin have different biological and analytical characteristics and should be interpreted in the appropriate clinical context.

Can this test alone diagnose acute myocardial infarction?

No. Cardiac biomarker results should be interpreted together with clinical symptoms, ECG findings, patient history and other diagnostic information. A rapid biomarker result alone should not be used as the sole basis for diagnosing or excluding acute myocardial infarction.

Is this a qualitative or quantitative cardiac marker test?

The current COEI product is intended for qualitative detection of cTnI, CK-MB and Myoglobin.

Who typically purchases cardiac marker combo rapid tests?

Typical B2B purchasers include IVD distributors, hospital procurement organizations, medical diagnostic importers, laboratory suppliers and POCT solution providers.

 

Request cTnI/CK-MB/Myo Combo Test Information

 

Looking for a cTnI/CK-MB/Myo Combo Rapid Detection Kit for your cardiac diagnostic portfolio?

Contact COEI for product specifications, packaging information, storage requirements, technical documentation, bulk purchasing and distributor cooperation.

Product Inquiry

Leave your phone number and we will contact you as soon as possible

Submit

*Note: Please fill in the information accurately and keep the communication open. We will contact you as soon as possible.

%E7%AC%AC%E4%B8%80%EF%BC%8C%E6%9C%80%EF%BC%8C%E4%BC%98%E7%A7%80%EF%BC%8C%E5%A2%9E%E5%BC%BA%EF%BC%8C%E4%B8%80%E6%B5%81%EF%BC%8C%E5%8D%93%E8%B6%8A%EF%BC%8C%E9%A2%86%E5%85%88%EF%BC%8C%E5%85%88%E8%BF%9B%EF%BC%8C%E5%BC%95%E9%A2%86

Sorry,当前栏目暂无内容!

您可以查看其他栏目或返回 首页

Sorry,The current column has no content!

You can view other columns or return Home